Marine Cable >> DIN 89158-89160 >> Communication And Control Cable >> Halogen FreeMarine Communication Cable-FMKHC
Marine Communication Cable-FMKHC
Description
Halogen Free Communication Cable with screen(armour)
Standard
DIN89159(German Standard)
Type Approval Certificates
ABS,BV,CCS,DNV,GL,KR,LR,NK.
Ship Cable Construction
1.Conductor
Annealed Standard Copper,class2.
2.Insulation
XLPE(Cross-Linked Polyethylene)
3.Laying Up
Pair stranding(2 pair Cable=quad stranding)
4.Armour
Separator tape,bare Copper braid
5.Outer sheath
Polyolefin
Electrical Characteristics
Rated Voltage Uo/U(Um)
150/250V
Test Voltage
2000V
Usage Characteristics
Max.Conductor temperature in service
90 Centigrade
Short-circuit max.conductor temperature
250 Centigrade
Minimum installation temperature
10 Degrees below zero centigrade
Minimum operating temperature
35 Degrees below zero centigrade
Flame retardant
IEC 60332-3 Cat.A
Smoke Density
IEC 61034
Gases corrosivity
IEC 60754-2
Gases toxicity
No toxicity to IEC 60754-1
Electro magnetic interference resistance
YES
Minimum internal bending radius
6*Cable Diameter
Applications
*For fixed installations in communication,radio,Control,data processing facilities on ship and offshore.
*The ship Cable meet the flame test requirements for bunched.(IEC 60332-3,IEEE 45-18.13)
*Halogen Free Cable materials ensure non corrosive and low toxic gases emitted in case of fire.
*Especially suitable for installation on passenger ships.

Product List

Product No. Pair No. Cross Section Outer Diameter Approx.Weight
(mm2) Min(mm) Max(mm) kg/km
MECA602-FMKHC01 1 0.75 7.5 8 90
MECA602-FMKHC02 10 0.75 18 20.6 460
MECA602-FMKHC03 14 0.75 20 22.5 610
MECA602-FMKHC04 19 0.75 23 25.5 750
MECA602-FMKHC05 2 0.75 8.5 9.8 130
MECA602-FMKHC06 24 0.75 26 28.8 920
MECA602-FMKHC07 4 0.75 11.5 14 230
MECA602-FMKHC08 7 0.75 14.5 17 330

Click here to contact me!