Function:
The purpose of a bridge navigational watch alarm system(BNWAS)is to monitor bridge activity and detect operator disability which could lead to marine addidents.The system monitors the awareness of the Officer of the Watch(OOW)and automatically alerts the Captain or another qualified OOW if for any reason the OOW becomes incapable of performing the OOW鈥檚 duties. This purpose is achieved by a series of indications and alarms to alert first the OOW and, if he is not responding, then to alert the Captain or another qualified OOW.Additionally,the BNWAS may provide the OOW with a means of calling for immediate assistance if required. The BNWAS should be operational whenever the ship鈥檚 heading or track control system is engaged, unless inhibited by the Captain.
BNWAS Environmental conditions:
Operating temperature:
indoor5℃~55℃銆乷utdoor -25℃~55℃
Relative humidity:
30%~90%;
Barometric pressure:
86KPa~106KPa.
System technical specification:
power supply: main power DC24v+30%,−25%;emergency power DC24+30%,−25%; AC220±10% optional;
Response speed of the operated key less than 0.1s;
Response speed of the external unit less than 1s;
Alarm sound level higher than wheel house fixed sound level 10dB;
Contact capacity of alarm not less than 1A 125VAC/2A 24VDC;
Communication distance: the distance between main unit and alarm panel or reset panel less than 1000M.