Marine Generator >> Diesel Generator >> Volvo >> 505KW Volvo Marine Diesel Genset
Product Name
505KW VOLVO Marine Diesel Generator Set
Product NO.
MPPS001-V505
Genset
Rating Range
MODEL
MPPS001-V505
Prime Power
505KW/631KVA
Standby Power
560KW/700KVA
Frequency
50Hz
Rated Speed
1500rpm
Weight(kg)
4050(kg)
Overall dimension (L*W*H)
3400*1380*2050(mm)
Generator Set Data
Voltage Regulation
≥±5%
Voltage Regulation, Stead State
≤±1%
Sudden Voltage Warp (100% Sudden Reduce)
≤+25%
Sudden Voltage Warp (Sudden Increase)
≤-20%
Voltage STABLE Time (100% Sudden Reduce)
≤6S
Voltage STABLE Time (Sudden Increase)
≤6S
Frequency Regulation, Stead State
≤ 4%
Frequency Waving
≤ 1.5%
Sudden Frequency Warp (100% Sudden Reduce)
≤ 12%
Sudden Frequency Warp (Sudden Increase)
≤ -10%
Frequency Recovery Time (100% Sudden Reduce)
≤ 5S
Frequency Recovery Time (Sudden Increase)
≤ 5S
Noise Level
116dB
Diesel Engine
Engine Data
Manufacturer / Model
VOLVO TWD1643GE, 4-cycle
Air Intake System
Turbo, Water charge Air Cooling
Fuel System
Elec. Injection, Elec. Fuel System
Cylinder Arrangement
6 in line
Displacement
16.12L
Bore and Stroke
144*165(mm)
Rated RPM
1500rpm
Compression Ratio
16.5
Power at Rated RPM
596KW/811HP(with fan)
Governor Type
EMS2
Exhaust System
Exhaust Gas Flow
111.8m³/min
Exhaust Temperature
463Celsius
Max Back Pressure
10kPa
Air Intake System
Max Intake Restriction
5kPa
Burning Capacity
46.96m³/min
Air Flow
780m³/min
Fuel System
100%(Prime Power) Load
199 g/KWh
75%(Prime Power) Load
196 g/KWh
50%(Prime Power) Load
196 g/KWh
Total Fuel Flow
190L/h
Oil System
Total Oil Capacity
48L
Oil Consumption
0.11L/h
Engine Oil Tank Capacity
42L
Oil Pressure at Rated RPM
300-650kPa
Cooling System
Total Coolant Capacity
128L
Thermostat
82-92Celsius
Max Water Temperature
103Celsius
Alternator
Alternator Data
Number of Phase
3
Connecting Type
3 Phase and 4 Wires, Y type connecting
Number of Bearing
1
Power Factor
0.8
Protection Grade
IP23
Altitude
≤± 1000m
Exciter Type
Brushless, self-exciting
Insulation Class, Temperature Rise
H/H
Telephone Influence Factor (TIF)
< 50
THF
< 2%
Voltage Regulation, Steady State
≤± 1%
Alternator Capacity
635KVA
Alternator Efficiencies
95.10%
Air Cooling Flow
1.035m³/s
Controller
Control System options: Key Start, Automatic AMF, ATS, Remote Control, Parallel System and Synchronization System etc.